Section 1001 11 of the irc 2006 edition exception 4.
Gas fireplace mantel clearance code.
B vented gas fireplaces usually have mantel requirements that will exceed this clearance.
Note some fireplaces esp.
Builders and do it yourself masons in california must follow building codes when they plan to install a fireplace in a residential or commercial property.
Your firebox wall needs to be 8 inches thick when lined with fire bricks or 10 inches thick without fire bricks.
Mantel brackets and corbels at the sides of the firebox opening require extra clearance if they project more than 1 5 inches outwards from the face of the fireplace.
In addition if the side panels of your mantel project more than 1 1 2 inches from the fireplace facing you will need additional clearance equal to this projection.
The national fire code dictates that any combustible material e g wood mantel or similar trim must be at least six inches from the firebox opening.
The icc though suggests at least 12 inches.
Mantel corbels and brackets attached along the sides of the opening must have additional clearance if they project more than 1 1 2 inches out from the face of the fireplace.
Also any part of the mantel that sticks out more than 1 5 inches from the wall s face over the opening needs to be at least 12 inches from the top of the fireplace opening.
Combustible materials and trim must be at least 6 inches from the firebox opening.
An additional inch of clearance is needed for every 1 8 inch the combustible material or trim protrudes.
National standard building code.
Zero clearance manufactured fireplace information.
Also vent free gas fireplaces will have a much greater clearance.
If your side panels jut out 2 inches from the facing an additional 2 inches of clearance will be needed from the fireplace opening to the sides of the mantel assembly.
Of a fireplace opening.
A clearance of not less than 8 inches 203 mm shall be provided between the gas tight capping slab of the heater and a combustible ceiling.
If your mantel extends more than an inch and a half out from the fireplace opening you should have more than a 6 inch clearance.
Masonry heaters listed and labeled in accordance with ul 1482 or cen 15250 shall be installed in accordance with the listing specifications and the manufacturer s written instructions.